Moisture Analyzer for Grains Compared with the Oven Method
By Lim Xu, Export Manager
A moisture analyzer for grains dries a ground sample and reports weight loss. How it compares with the ISO 712-1 oven method and grain moisture meters.
A moisture analyzer for grains weighs a ground sample, dries it under a halogen lamp and reports moisture from the loss in weight. The reference for most cereals is still an oven method. What matters is how closely your analyzer matches that reference on your own grain.
Why grain moisture is measured
Moisture sets the value of a grain lot. NIST Handbook 159 explains that grain moisture decides how much a seller is paid. Grain that is too wet has to be dried before storage, and grain that is too dry may lose quality.
Moisture also corrects other results. USDA's Federal Grain Inspection Service uses the moisture value to adjust protein, oil and starch to a constant moisture basis.
Inside a mill or a feed plant, the same number drives drying, blending and storage decisions. That is why labs want a result they can trust and get quickly.
Reference oven method for cereals
For most cereals the reference is ISO 712-1. It applies to wheat, rice, barley, millet, rye, oats, triticale and sorghum, as grains, milled grains, semolina or flour. It does not cover maize or pulses, which have their own methods in ISO 6540 and ISO 24557.
The earlier edition, ISO 712:2009, describes the principle. The sample is ground if needed, then a test portion is dried in an oven held between 130 °C and 133 °C. The conditions are set so that the result matches an absolute method given in its annex.
In the United States, the air oven is the reference method for grains and oilseeds. FGIS weighs a representative sample, dries it in a standardized forced draft oven and weighs it again. AACC Approved Method 44-15.02, Moisture Air-Oven Methods, is another oven method used in cereal labs.
An NPL review of loss on drying methods calls oven drying a fundamental method that needs no calibration. Its drawback is time, since drying can take hours. Our guide to moisture analyzers for food covers the same reference check for other food materials.
Halogen moisture analyzer method for grain
A halogen moisture analyzer is a bench instrument with a heater and a balance in one unit. It reports the mass lost while the sample heats. The NPL review notes that this counts all volatiles, not water alone, so the result is moisture as loss on drying.
Not sure how your grain will behave on a halogen analyzer? Tell us what you need to test. We test a similar material sample and send you the video, so you do not need to ship a sample. If you prefer to send your own, we accept that too.
Grinding and sample size
The 2009 edition of ISO 712 grinds grain unless it is already fine enough. Its mill has to work fast and evenly without raising the sample temperature by more than 5 °C. NIST Handbook 159 adds that ground grain should be kept tightly sealed, with little time between grinding and weighing.
Use the same mass and the same spread on the pan in every run. Our KHT-HMA-01 halogen moisture analyzer takes samples up to 110 g and weighs to 0.001 g. Whether it suits your grain and your method is something to confirm with us first.
Drying temperature and end point
ISO 712 fixes an oven temperature range, not a halogen setting. A halogen program for grain has to be found by testing it against the oven result on the same material. The KHT-HMA-01 sets the drying temperature from 40 °C to 160 °C in 1 °C steps.
The end point needs the same care. The NPL review notes that loss on drying protocols differ in temperature, time and end point rules. Our guide to halogen moisture analyzer temperature settings shows how to run a temperature study step by step.
Halogen analyzer vs grain moisture meter
Most grain moisture meters are indirect. The NPL review groups capacitance, conductance, near infrared and microwave methods as indirect techniques. They are quick and leave the grain intact, but each one has to be calibrated against a direct method such as loss on drying.
Those meters are also sensitive to the grain itself. NPL lists density, conductivity and surface effects among the things that change capacitance and conductance readings.
In US official inspection, moisture meters must give results equivalent to the air oven method and use approved calibrations for each grain. NIST Handbook 159 asks inspectors to check that a meter has current calibrations for every grain traded at a site.
A halogen analyzer measures loss on drying directly, so it does not need a calibration for each grain. It does need a drying program matched to the reference method. It also takes longer per sample than a meter and needs the grain ground first.
Checking results against the reference method
The NPL review says indirect methods are checked by applying both methods to the same batch and comparing the results. Use the same approach for a halogen analyzer.
- Split one well mixed, ground sample into matched portions
- Test some portions in the oven and some on the halogen analyzer
- Compare the averages and record the difference for each grain
- Repeat at low and high moisture levels for every grain you test
NIST Handbook 159 asks labs to calculate and keep the bias between a meter and the air oven for each working sample. Keep the same kind of record for your halogen program, and review it when the grain type or the season changes.
Frequently asked questions
Can a halogen analyzer be used for official grain grading?
In US official inspection, moisture is measured with meters approved by USDA. A halogen analyzer suits in-house checks, as long as its results have been compared with the reference oven method.
Does ISO 712-1 cover maize?
No. ISO 712-1 excludes maize and pulses. Maize moisture is covered by ISO 6540, and pulses by ISO 24557.
Does a test video replace a quotation?
No. The video shows the method on a similar material sample. For a quotation, tell us the grains you test, how many samples you run a day and the method you check against.
Get a test video for your samples
Tell us what you need to test, such as the material, the size and the test method. We test a similar material sample on the instrument you are looking at and send you the video, so you do not need to ship a sample. If you prefer to send your own, we accept that too.